Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/deluxe/public_html/sites/all/modules/xautoload/src/Util.php on line 127

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/deluxe/public_html/sites/all/modules/xautoload/src/Util.php on line 164

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/deluxe/public_html/sites/all/modules/xautoload/src/ClassFinder/ClassFinder.php on line 417

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/deluxe/public_html/sites/all/modules/xautoload/src/ClassFinder/ClassFinder.php on line 460

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/deluxe/public_html/sites/all/modules/xautoload/src/ClassFinder/Plugin/DrupalExtensionNamespaceFinderPlugin.php on line 185

Deprecated: Unparenthesized `a ? b : c ? d : e` is deprecated. Use either `(a ? b : c) ? d : e` or `a ? b : (c ? d : e)` in /home/deluxe/public_html/sites/all/modules/httprl/httprl.module on line 262

Deprecated: The behavior of unparenthesized expressions containing both '.' and '+'/'-' will change in PHP 8: '+'/'-' will take a higher precedence in /home/deluxe/public_html/sites/all/modules/advagg/advagg.module on line 3169

Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/deluxe/public_html/profiles/commerce_kickstart/modules/contrib/search_api/search_api.module on line 1479
Prag 1.5KVA/24V Solar Inverter + AC/DC cables | Deluxe Nigeria
Call To Place an Order: 09094789078, 012931712, 07010189956
  • Pay on deliveryPay On Delivery
    Lagos Only
  • Fast Shipping
    1 - 3 Days
  • Free Delivery in Lagos
    Order above N500,000

Empty

Total: ₦0.00
SiteLock

Prag 1.5KVA/24V Solar Inverter + AC/DC cables

SKU:
DELUXE-V1520692762
Price:₦156,554
Weight: 
18.5 kg
Brand: 
Prag
1.5KVA/24V Solar Inverter + AC/DC cables
Description: 


High reliable system

Advanced digital automatic control technology to ensure the power durable and
reliable

Strong Environment
Adaptability

  • Wide
    input voltage and frequency range to avoid frequent switching.
  • Intelligent
    charging mode.
  • Shutdown
    charging function.
  • Three
    steps charging mode

Full Display Information

  • LED
    display: AC, PV, Inverter output, fault, charge, battery low.
  • LCD
    Display: Input voltage, Input frequency, Output voltage, Output frequency,
    Battery voltage, PV input voltage, Solar charger, Full load, Temperature,
    Failure.

 

LCD+LED Display Mode

Full
Display Function

  • Inverter
    short circuit and overload protection function.
  • Battery
    over discharge protection.
  • Solar
    cell module polarity reverse connection protection.
  • Solar
    charge controller, inverter and other internal short circuit protection.

Features:

  • Wide
    input voltage range
  • Fully
    digitized microprocessor control
  • UPS
    mode and inverter mode suit for different application
  • LED
    indicates the status
  • LCD
    displays comprehensive parameters (Optional)
  • Cold
    start
  • Short
    circuit and overload protection
  • Intelligent
    battery management
  • Changing
    current is optional
  • Compatible
    with generator

Specifications


Model

1.5KVA-SOLAR-INV-KS

Capacity (KVA/KW)

1.5/1.2

Line Mode

Input

Nominal input Voltage

220V (AC)

Operating Voltage Range

145V ~ 285V (AC) UPS Mode)

120V ~ 300V (AC) (Inverter Mode)

Operating Frequency Range

38Hz ~ 70Hz

Output

Voltage

200V ~ 240V (AC) UPS Mode)

180V ~ 255V (AC) (Inverter Mode)

Frequency Range

Same as Mains

Waveform (Mains, Mode)

Tracking Mains

Efficiency

>95% (Full R Load and Battery Full Charged)

Transfer Time

UPS mode (High Sensitivity); 8ms typical, 10ms Max.

Inverter Mode (Low Sensitivity); 140ms Max, (Slow Start)

Back Up Mode

Output

Voltage

220V (AC) (±5%)

Frequency Range

50 ±1Hz

Waveform (Batt. Mode)

Pure Sine Wave

Efficiency

≥ 83%

AC Charger

Charging Algorithm

3-Step Charging

Maximum Charging Current

10A / 20A Selectable

Floating Charging Voltage

27.6V (DC)

Over Charging Voltage

30V (DC)

Solar Charger

Maximum PV Array Power

1200W

Maximum Charging Current

50A

Battery Voltage

24V (DC)

Operating Voltage

30 ~ 36V (DC)

Maximum PV Array Open Circuit Voltage

65V (DC)

Typical Recharge Time

Depended on external battery

Protection

Full Protection

Overload, Over Charged, Over Discharged, Over Temperature, Short
Circuit Protection

Alarm

Battery Mode

Beep 1 time/10s, Mute after 3min

Battery Low

Period: Beep 2 times/s, then mute 1 second

Overload

Beep 4 times in 3s, then mute 2s

UPS Start-up

Beep for 2s

Fault

Continuously Sounding

Physical

Dimension (DxWxH) mm

362.5 x 295 x 187.3

Packing (DxWxH) mm

424 x 385 x 272

Net Weight (kg)

18.5

Shipping Weight (kg)

20

Operating Environment

Humidity

0~90% RH @ 0~40°(Non-Condensing)


Noise Level

Less than 50dB